Negotiable
The date of payment from buyers deliver within days
Guangdong
Long-term effective
2017-12-12 22:55
40
Company Profile
Yangzhou Bright Solar Solutions Co., Ltd.By certification [File Integrity]
Contact:Mr. Tom Li(Mr.)
Email:
Telephone:
Phone:
Area:Guangdong
Address:Guangdong
Website: http://kemapower.cqfhchina.com/
Item | Model | G-PSW-1K | G-PSW 2K | G-PSW3K |
Capacity | VA / Watts | 1KVA/1KW | 2KVA/2KW | 3KVA/3KW |
Surge rating (10s) | 3KVA | 6KVA | 9KVA | |
Efficiency | >95% under AC mode,>88% under DC mode | |||
Power Factor | 0.9~1.0 | |||
Input | Normal voltage | 220VAC/110V | ||
220V Voltage range | 184-270V+-4% | |||
110V Voltage range | 85-150V+-4% | |||
Frequency range | 50Hz/60HZ -3 +5 Hz (Auto detection) | |||
Output | Voltage (V) | 220V/110V+-10% | ||
Frequency (Hz) | 50Hz/60HZ +-0.3 Hz | |||
Wave form | Pure Sine Wave | |||
bypass without Battery | yes | |||
UPS Mode | Grid power first. Battery power ( Solar Power) as backup | |||
Solar inverter Mode | Solar Power First, Grid power as Backup | |||
Transfer Time | less than 10 ms (typical) | |||
Overload capacity | DC Mode(SMPS load) | (110%<load<125%) ±10% for 15 minutes; (125%<load<150%) ±10% for 60s; Load>150% ±10% for 20s | ||
AC Mode(SMPS load) | by breaker | |||
Protection | Overload | Current limit under DC mode ,Breaker under AC mode | ||
Battery Protection | Over charge, Over discharge,DC Breaker,Alarm | |||
Over Temperature | Variable speed fan,LED lighting and alarm | |||
Back-Feed Protection | yes | |||
short Circuit. | by breaker.Faul after 10 secs | |||
Battery/Charger | AC input | 95-127V, 194(164)--243V | ||
DC input | 12VDC /24VDC or 48VDC,external Battery | |||
Charge Voltage | for 12VDC system,Boost voltage 14-15.5V selectable for different Battery. The others are multiple | |||
Charger Current | 12-75AMP difference for different mode | |||
Charge Manage | digital control,Three stage charger | |||
Display | LED | Line On/ Inverter on / Fast Charger / Float charge / Over Temp. trip / Over load trip / Power Saver on | ||
Audible Alarm | Battery Low,Battery High,Over Temp. Over load,Fail,Over charge | |||
Optional | RS232 Communication,SNMP Net Agent,Remote Control | |||
Power Saver | below 25W when enabled.loading checking 2 time/sec. | |||
Working Environment | Temperature | 0°C to 40°C | ||
Noise | 60dB max | |||
Humidity | 5% to 95% | |||
Package | Carton | Carton | Carton | |
Package Size | WxDxH (mm) | 590*335*320 | 590*335*320 | 590*335*320 |
Gross Weight | 20 | 22 | 26 | |
ATTENTION | the inverter do not build in solar charger controller. |